Loading presentation...

Present Remotely

Send the link below via email or IM

Copy

Present to your audience

Start remote presentation

  • Invited audience members will follow you as you navigate and present
  • People invited to a presentation do not need a Prezi account
  • This link expires 10 minutes after you close the presentation
  • A maximum of 30 users can follow your presentation
  • Learn more about this feature in our knowledge base article

Do you really want to delete this prezi?

Neither you, nor the coeditors you shared it with will be able to recover it again.

DeleteCancel

Make your likes visible on Facebook?

Connect your Facebook account to Prezi and let your likes appear on your timeline.
You can change this under Settings & Account at any time.

No, thanks

Analisa Kelayakan Heat Exchanger di Central Gathering Statio

No description
by

arina sunaryo

on 31 May 2014

Comments (0)

Please log in to add your comment.

Report abuse

Transcript of Analisa Kelayakan Heat Exchanger di Central Gathering Statio

Analisa Kelayakan
Heat Exchanger
di
Central Gathering Station-5
dengan HYSYS 3.2
PT.Chevron Pacific Indonesia

Sejarah PT. CPI
1924 : Terbentuknya tim SOCAL (Standard Oil Company of California
1930 : SOCAL menjadi minority partner Hindia-Belanda
1936-1941 : ditemukan ladang minyak di Sebanga, Rantaubinas, Duri di Pulau Sumatera
1950 : Berdirinya PT. Caltex Pacific Oil Company (CPOCC) di Indonesia
1963 : CPOCC berubah nama menjadi PT. Caltex Pacific Indonesia
2005 :PT. Caltex Pacific Indonesia berubah nama menjadi PT.Chevron Pacific Indonesia
Duri Heavy Oil Overview
Central Gathering Station-5 Overview
Oil Treating Plant Overview
Saran
1. Diperlukan pembersihan pada HE karena nilai Rd dan ΔP shell telah melewatri batas yang diijinkan. Pembersihan dilakukan secara mekanik/kimia

2. Hysys 3.2 dapat digunakan untuk menganalisa kebutuhan steam yang sesuai dengan suhu crude oil masuk HE, sehingga suhu keluaran HE dapat dicapai

Tugas Khusus
Analisa HE di CGS-5 dengan HYSYS 3.2
Latar Belakang:

1. Jenis minyak di lapangan minyak Duri adalah Heavy Oil
2. Karakteristik: API <<, Viskositas >>, kadar lilin&belerang >>, mudah membeku
3. Diperlukan HE
4. Analisa kerja HE dengan HYSYS 3.2
Tujuan
1. Melakukan simulasi HE dengan HYSYS.3.2
2. Menganalisa kerja HE dari simulasi dengan HYSYS 3.2
Design HE di CGS-5
Analisa Kelayakan HE
Menurut Kern (1950):
1. Fouling Factor (Rd)
2. Pressure drop (dP)

di PT. CPI
1. kebutuhan steam
Hasil Simulasi HYSYS 3.2
Tinjauan Pustaka
Hasil Simulasi
Pembahasan
1. Rd aktual (0,000635 hr.ft2/BTU. F) > Rd design (0,000301 hr.ft2/BTU.F) --> terdapat pengotor dalam HE
2. ΔP shell aktual (5,2 psia) > ΔP shell design (3 psia) dan ΔP tube aktual (1,18 psia) < ΔP tube design (5 psia)  endapan terjadi pada bagian shell
TERIMA KASIH
3. Hasil simulasi hysys 3.2 penggunaan steam 10000 bbl/day tidak dapat menaikkan suhu crude oil 22419 bbl/day sesuai target (170-200ºF). Artinya, steam 10000 bbl/day tidak mencukupi sesuai target. Dapat disimpulkan, penggunaan steam dipengaruhi oleh suhu masuk HE. Semakin rendah suhu crude oil masuk HE maka steam yang dibutuhkan semakin banyak
Pembahasan (lanjutan)
HYSYS 3.2