Loading presentation...

Present Remotely

Send the link below via email or IM

Copy

Present to your audience

Start remote presentation

  • Invited audience members will follow you as you navigate and present
  • People invited to a presentation do not need a Prezi account
  • This link expires 10 minutes after you close the presentation
  • A maximum of 30 users can follow your presentation
  • Learn more about this feature in our knowledge base article

Do you really want to delete this prezi?

Neither you, nor the coeditors you shared it with will be able to recover it again.

DeleteCancel

Make your likes visible on Facebook?

Connect your Facebook account to Prezi and let your likes appear on your timeline.
You can change this under Settings & Account at any time.

No, thanks

Earth Simulator

No description
by

Prodan Iuliana

on 4 June 2010

Comments (0)

Please log in to add your comment.

Report abuse

Transcript of Earth Simulator

Earth Simulator Prodan Iuliana
iuliana.prodan@gmail.com
Grupa 335CA Ce este Earth Simulator? Cel mai rapid calculator din lume intre 2002 si 2004

Sistem dezvoltat pentru rularea de modele climatice pentru a putea fi evaluate efectele incalzirii globale

Pe el pot fi rulate simulari climatice (atmosferice si oceanice) pana la o rezolutie de 10 km
Arhitectura hardware ES este format din 640 PNs conectate intre ele de 640x640 single-stage crossbar switches

Fiecare PN (Processor Node) este un sistem cu memorie shared, format din cate 8 procesoare aritmetice, 16GB memoria principala a sistemului(MS), o unitate de control(RCU) si un procesor I/0

RCU (Remote-access Control Unit) este direct conectat la switch-urile crossbar si controleaza comunicatia datelor inter-nod

PN – valoarea maxima a throughput-ului se obtine prin accesarea datelor contigue care se afla in locatii de memorie ce au adresele in ordine crescatoare Procesorul aritmetic Fiecare AP (Arithmetic Processor) este format dintr-o unitate scalara pe 4 directii (SU), o unitate vectoriala (VU) si unitatea de control a memorie aflata pe un singur chip LSI
AP are o frecventa a ceasului de 500MHz(unele circuite opereaza la 1GHz)
Fiecare SU (Super-scalar Unit) este un procesor super-scalar cu 64KB instructiuni cache, 64KB data cache si 128 registri generali
Fiecare VU (Vector Unit) are 72 registri vectoriali, fiecare avand cate 256 de elemente vectoriale.
Arhitectura software Sistemul de operare

Este o versiune avansata a sistemului de operare NEC’s Unix numit “SUPER-UX”, care este dezvoltat pentru supercalculatoarele NEC’s SX Series

are scalabilitate mare
furnizeaza caracteristici speciale pentru ES Furnizeza caracteristicile de I/O ale lui ES.
Permite manipularea mai multor fisiere care sunt localizate in disk-uri separate ale PNs.
Fiecare proces al unui program poate scrie/citi date distribuite de la/catre un fisier cu o singura I/O declarare pentru a obtine performante ridicate de utilizare pentu I/O.
Parallel File System Limbaje de programare Sunt disponibile compilatoare pentru FORTRAN 90 , C si C++(numite FORTRAN90/ES, C/ES respectiv C++/ES ).

Toate acestea au o capacitate avansata de vectorizare automata si microtasking.

Microtasking este un fel de multitasking prevazut la inceput pentru supercalculatoarele Cray , aceeasi functie fiind folosita si la paralelizarea unui intra-nod pentru ES.

OpenMP este deasemene folosit in FORTRAN 90 si C++ pentru paralelizarea unui intra-nod
Locatia ES Sistemul de protectie contra fulgerelor

Patru poli la ambele capete ale cladirii ES alcatuiesc o “panza” de cabluri pentru protectia cladirii impotriva fulgerelor.
Sursa de lumina

Lampa cu halogen de 1kW
Sistemul de protectie contra seismelor

11 isolatoare (1ft inaltime, 3.3ft. diametru, 20-straturi de cauciuc)
Proiecte Simulari atmosferice pentru Agentia Aerospatiala a Japoniei

Simulari atomice pentru Insititutul Japonez de Cercetari Atomice

Simulari oceanice pentru Centrul Japonez de Stiinte si Tehnologii Marine

Simulari industriale
Earth Simulator 2 de 3 ori mai rapid

160 PNs fata de 640

131 Tflops de 3.2 ori mai mult fata de 40Tflops

20-30% mai putin consum energetic

650 metri patrati fata de 3250 Va multumesc