Loading presentation...

Present Remotely

Send the link below via email or IM

Copy

Present to your audience

Start remote presentation

  • Invited audience members will follow you as you navigate and present
  • People invited to a presentation do not need a Prezi account
  • This link expires 10 minutes after you close the presentation
  • A maximum of 30 users can follow your presentation
  • Learn more about this feature in our knowledge base article

Do you really want to delete this prezi?

Neither you, nor the coeditors you shared it with will be able to recover it again.

DeleteCancel

Make your likes visible on Facebook?

Connect your Facebook account to Prezi and let your likes appear on your timeline.
You can change this under Settings & Account at any time.

No, thanks

PROYECTO ELECTRICO

No description
by

Javier Medina

on 7 September 2015

Comments (0)

Please log in to add your comment.

Report abuse

Transcript of PROYECTO ELECTRICO

PROYECTO ELECTRICO
PLANTEAMIENTO DEL PROBLEMA
Identificar las necesidades:
Obra Nueva que consiste en un Hotel de 20 Pisos, un piso de Acceso, dos pisos de Sala de Conferencias, quince pisos de Habitaciones, un piso de bar comedor y Piscina, un piso de Gimnasio, baños y Asotea con equipos como: sala de Calderas, equipos de Refrigeración y equipos de Extracción.

"Generar Sistema eléctrico que transforme, alimente y distribuya a Edificio Hotel".

OBJETIVO GENERAL
Desarrollar estudio previo.
Aplicar criterios en diseño de proyectos eléctricos.
Reconocer y aplicar normativa eléctrica vigente.
Desarrollar proyecto en Autocad.
Ejecución de proyecto eléctrico.

MEMORIA EXPLICATIVA
En NCH.Elec. 2/84 en el capitulo 6, habla de las condiciones generales para todo tipo de proyectos eléctricos.

Se define en cuatro partes:

Descripción de la Obra
Cálculos Justificativos
Especificaciones Técnicas
Cubicaciones de Materiales





DESCRIPCION DE LA OBRA
CALCULOS JUSTIFICATIVOS
HOTEL TERRADO CAVANCHA
UNIVERSIDAD DE TARAPACA
Escuela Universitaria de Ingeniería
Eléctrica Electrónica

Plantear, Elaborar e Implementar un Proyecto de Ingeniería Eléctrica.
OBJETIVOS ESPECIFICOS
NCH. ELEC. 2/84.
NCH. ELEC. 4/2003.
NSEG.20_78.
NSEG.8_75.
NSEG.16_78.
Normas Utilizadas:
La obra consiste en una nueva construcción de edificio Hotel Terrado Cavancha ubicado en Tadeo Haenke esquina Arturo Prat, en la comuna de Iquique, región de Tarapacá.
Receptores:
Descripción de la Obra
Cálculos Justificativos
Especificaciones Técnicas
Cubicación de Materiales
Descripción de la Obra
Cálculos Justificativos
Especificaciones Técnicas
Cubicación de Materiales
Se define Potencia Total Instalada, luego se estima mediante factores la Potencia Total Demandada.
Según NCH.ELEC.4/2003 Tabla N°7.5, para el caso de Hoteles:
Los primeros 20KW considera factor 0,5,
Desde 20KW a 100KW considera factor 0,4.
Sobre los 100KW considera factor 0,3.

PROYECTO ELECTRICO
ESPECIFICACIONES TECNICAS
Las Especificaciones Técnicas contienen las características de funcionamiento, designación de tipo, características de instalación, dimensionales, constructivas, y de materiales si procede. Las E.T.E. son las que esclarecen en caso que los planos no sean lo suficientemente claros o se presente alguna duda.
Descripción de la Obra
Cálculos Justificativos
Especificaciones Técnicas
Cubicación de Materiales
DIMENSIONAMIENTO DEL TRANSFORMADOR
Descripción de la Obra
Cálculos Justificativos
Especificaciones Técnicas
Cubicación de Materiales
La Potencia demandada es: Pd=545,42 KW

Considerando Factor de Potencia Mejorado Fp=0,95

se tiene: S=(Pd/Fp)=574,13 KVA

Por lo tanto, la potencia Comercial del Transformador es de 630 KVA.

Se debe tener presente lo sgte:

Tipo de Conexión, Grupo Vectorial.
Tipo de Refrigerante.
Nivel de Aislación.
Nivel de Voltaje primario y secundario.
Taps
Consideraciones Técnicas de Instalación.


Consideraciones:
Nivel de Tensión Primario 13,2KV
Nivel de Tensión Secundario 0,22/0,4 KV
DIMENSIONAMIENTO ALIMENTADOR PRINCIPAL
Descripción de la Obra
Cálculos Justificativos
Especificaciones Técnicas
Cubicación de Materiales
Desde T/F a T.G.
Potencia Instalada : 763,67 kW
Largo : 26 mts. Vp(%)=2 --> Vp=8V

Sección mínima:
Sm = (L*P) / (k*Vp *V) = (26 * 763,67) / (56 *8 *400) = 110,80mm2

Donde
L = Largo del alimentador [m].
P = Potencia Trifásica activa [w].
k = Coeficiente de resistividad [m/(Ohmn*mm²)] (Tabla 3.2.8)
Vp = Caída de tensión máxima [v].
V = Voltaje de alimentación [400V]


Considerando un conductor de sección 177mm2, se tiene:

Vp = (L*P) / (k *Sm*V) = (26*763,67) / (56*177*400) = 5,27V

Vp(%) = Vp / V = 5,27 V / 400V = 1,32%



Alumno : Javier Medina Mancilla
Profesor Guía : Raul Sanhueza Hormazábal
Profesor Informante: Ildefonso Harnisch Veloso
Según Tabla N°8.7a NCH.ELEC.4/2003
de Corrientes Admisibles para conductores aislados.
Para una Potencia de 763,67KW se calcula una corriente de 1160 A. Para este caso se considera una sección total de 354 mm².


ej. 2 C x 1 x 350MCM =2x 177mm²
Notas:
• Cumple de acuerdo a normativa 7.1.1.3.- de NCH4/2003, con respecto a la caída de tensión máxima, no exceda el 3% de la tensión nominal.

CUBICACION DE MATERIALES
Descripción de la Obra
Cálculos Justificativos
Especificaciones Técnicas
Cubicación de Materiales
CALCULO PROTECCION GENERAL TERMOMAGNETICA
Descripción de la Obra
Cálculos Justificativos
Especificaciones Técnicas
Cubicación de Materiales
Pd = 545,42 KW
FP = 0,95
V= 400V
I = 872,39 (A)

Se considera una Protección Termomagnetica de 3x900 (A)
Capacidad
Ruptura
Tipo de Empalme
Detalle Subestación
Sistema de Puesta a Tierra
Alimentadores y Subalimentadores
Canalizaciones
Accesorios
Tableros Eléctricos y de Control. ( Extracción )
Características de Grupo Generador
PLANTEAMIENTO
DEL PROBLEMA
OBJETIVOS
GENERAL Y
ESPECIFICOS
MEMORIA
EXPLICATIVA
DESCRIPCION DE LA OBRA
CALCULOS JUSTIFICATIVOS
ESPECIFICACIONES TECNICAS
CUBICACION DE MATERIALES

ESTUDIO
GEOELECTRICO
DISEÑO DE
PLANOS
DISEÑO DE
UN SPT
CERTIFICACION
S.E.C.
ALIMENTADOR PRINCIPAL
PROTECCION GENERAL
DIMENSIONAMIENTO T/F
ESTUDIO GEOELECTRICO
DISEÑO DE PLANOS
En el diseño del proyecto, es fundamental tener presente la terminología adecuada, simbología, cuadros de cargas estándar, rótulos descriptivos y formatos según lo estipulado en normativa NCH ELEC 2/84.

Para la elaboración de este diseño se desarrolla un extracto de simbología que detalla cada uno de los elementos utilizados y emplazados en terreno.
PROYECTO ELECTRICO
PLANTEAMIENTO
DEL PROBLEMA
OBJETIVOS
GENERAL Y
ESPECIFICOS
MEMORIA
EXPLICATIVA
DESCRIPCION DE LA OBRA
CALCULOS JUSTIFICATIVOS
ESPECIFICACIONES TECNICAS
CUBICACION DE MATERIALES

ESTUDIO
GEOELECTRICO
DISEÑO DE
PLANOS
DISEÑO DE
UN SPT
CERTIFICACION
S.E.C.
ALIMENTADOR PRINCIPAL
PROTECCION GENERAL
DIMENSIONAMIENTO T/F
DISEÑO DE PLANOS
CERTIFICACION SEC
Una vez ejecutado el proyecto de acuerdo a lo proyectado según normativa, se prepara documentación para presentación al SEC, organismo que regula las instalaciones eléctricas.
EMPLAZAMIENTO DE EMPALME M.T.
Y SISTEMA DE PUESTA A TIERRA.
PLANTA DE ALUMBRADO
ENCHUFE Y MALLA
EQUIPOTENCIAL.
ESQUEMAS UNILINEALES, CUADRO DE CARGAS
Y PLANTA DE ALUMBRADO TIPO.
Factibilidad de Suministro de Eliqsa
Protocolo de pruebas de T/F
Certificado de Calibración Medidor
Certificado de Pruebas de Compacto
Certificado TE1