SISTEMA DE ÁGUA DE RESFRIAMENTO DAS UNIDADES GERADORAS E CAS

No description
by

on 30 October 2013

Comments (0)

Please log in to add your comment.

Report abuse

Transcript of SISTEMA DE ÁGUA DE RESFRIAMENTO DAS UNIDADES GERADORAS E CAS

Topic 2
Topic 3
Topic 4
Topic 5
Conclusion
SISTEMA DE ÁGUA DE RESFRIAMENTO DAS UNIDADES GERADORAS
E CASA DE FORÇA DA USINA SERRA DA MESA








Raimundo Alves Ferreira
Profissional Nível Médio Operacional – DMEB.O/GRB.O


Novembro de 2013.



OBJETIVOS

Este Trabalho tem como objetivos abordar, de maneira geral, o sistema de água de resfriamento das unidades geradoras e Casa de Força da Usina de Serra da Mesa, demonstrar as suas principais características e particularidades e mostrar os proOblemas existentes nesse sistema, bem como as soluções aplicadas até o momento.


CONSIDERAÇÕES INICIAIS


O sistema de água de resfriamento possui papel de destaque para o perfeito funcionamento das Unidades Geradoras, pois, além de estar diretamente ligada aos principais componentes das unidades geradoras, é responsável também, pelo funcionamento de importantes equipamentos auxiliares da Usina Serra da Mesa, Portanto, a manutenção desse sistema é de suma importância para a operação das Unidades Geradoras.

8

6

1

5

4

2

9

7

3

DIAGRAMA DO SISTEMA DE ÁGUA DE RESFRIAMENTO – USINA SERRA DA MESA

Sala do FAR 01 (Filtro Separador de Sedimentos) – UG #01 – UHSM

Captação da Água de Resfriamento – UG #01- UHSM

Filtro Separador de Sedimentos (Esq.) e Atuador e Válvula de Retro-lavagem
do FAR (Dir.) da UG#01 – UHSM


FILTROS DE ÁGUA BRUTA (Filtro Separador de Sedimentos):

-Tipo...........................................................Filtro Hero FPB 6000 LB – 16
-Número de Filtros.................................................................................3
-Vazão Nominal........................................................................1676 m3/h
-Filtragem Requerida....................................................................100 µm
-Filtragem do FAR da UG #03………………………………………………….760µm
-Perda de Carga, com Elemento Sujo.............................................30 kPa
-Código.............................................................................ASME VIII-Div. 1
-Pressão de Operação.................................................................1360 KPa
-Pressão de Projeto..................................................................1...350 kPa
-Pressão de Teste Hidrostático....................................................2500 kPa
-Princípio de Limpeza............................................................Backflushing
-Acionamento de Limpeza...................................................Moto-redutor
-Material dos Elementos...............................................................AISI 316


-Pressão de Entrada Máx: 1670kPa

-Pressão de Saída: 710 kPa

Válvula Reguladora de Pressão – UG#01- UHSM

Válvula Principal do Sistema de Água de Resfriamento – UG#02 – UHSM

VPAR.2

Atuador Pneumático

Trocador de Calor do Gerador (Radiador) UG#02 – USSM.O

Trocadores de Calor do Mancal de Escora do Gerador – UG #03 – UHSM

Trocadores de Calor do Mancal Guia do Gerador (Esq.) e Trocadores de Calor do Mancal Guia da Turbina (Dir.) – UG#02

PROBLEMAS EXISTENTES NO SISTEMA DE ÁGUA
DE RESFRIAMENTO E SOLUÇÕES APLICADAS


>PROBLEMAS DE OBSTRUÇÃO DO SISTEMA DE RESFRIAMENTO
(FILTROS, TUBULAÇÃO E TROCADORES DE CALOR DE TUBO E DE PLACAS)

>TRATAMENTO QUÍMICO UTILIZADO;

>INSTALAÇÃO DE SISTEMA DE LIMPEZA AUTOMÁTICA NOS TROCADORES DE CALOR
DO GERADOR (UNIDADES GERADORAS 02 E 03) , NOS TROCADORES DE CALOR
DA EXCITATRIZ E NOS TROCADORES DE CALOR DO MGG DA UNIDADE GERADORA 02;

>INSTALAÇÃO DE FILTROS DE CARTUCHO NO SISTEMA DE ÁGUA DE LUBRIFICAÇÃO
DOS CARVÕES DA CAIXA DE VEDAÇÃO DO EIXO DA TURBINA (UNIDADES GERADORAS 01, 02 03);

>LIMPEZA QUÍMICA DOS TROCADORES DE CALOR DO GERADOR COM UTILIZAÇÃO
DE UNIDADE DE LIMPEZA QUÍMICA REMOTA (UTILIZANDO ÁCIDO KLEEN AC 9505 E SODA CÁUSTICA).

Filtro Separador de Sedimentos (FAR) – UG#01 – UHSM

Trocadores de Calor (Radiador) da UG#02 – UHSM

CARTUCHOS FILTRO DA ÁGUA DE LUBRIFICAÇÃO DOS CARVÕES

INSERTS E ESCOVAS SIST. ATB DO TCG

PINOS DA CAIXA DE VEDAÇÃO

TUBULAÇÃO DE ÁGUA MGG

Placas do Trocador de Calor do Mancal de Escora – UG#01 – UHSM

Trocador de Calor da Excitatriz da UG#02 – UHSM

TRATAMENTO QUÍMICO

PRODUTOS UTILIZADOS:

• Hipoclorito de Sódio (NaClO) 10% - 12%: Age Contra a Ferrobacteria (Gallionella);
•Depositrol PY5201: Biodispersante e Inibidor de Corrosão

>DOSAGEM:
-Hipoclorito: 05 – 06 PPM, durante 15 minutos (intervalo de 24 h);
-Depositrol: 0,6 PPM, durante 15 minutos, paralelamente à dosagem de hipoclorito.


Dosadora de Hipoclorito de sódio e biodispersante – El. 313,00 – UHSM

SISTEMA ATB (AUTOMATIC TUBE BRUSHING)

Instalação das Escovas e Retentores nos Trocadores de Calor da Excitatriz – UG#02 – UHSM

Instalação das Escovas e Retentores nos TCG’S da UG#02 – UHSM

Montagem da Válvula 4 Vias no Sistema dos TCG’S da UG#02 – UHSM

Válvula 4 Vias Aberta para Inspeção e Reparo

VÁLVULA REVERSORA DE FLUXO – EXCITATRIZ UG #02

VÁLVULA REVERSORA DE FLUXO – TCG DA UG #03

Válvula Inversora de Fluxo do TCMGG – UG#02 – UHSM

FILTRO DE CARTUCHO – SISTEMA DE ÁGUA DE LUBRIFICAÇÃO DOS CARVÕES DA CAIXA DE VEDAÇÃO DO EIXO DA TURBINA

UNIDADE DE LIMPEZA QUÍMICA REMOTA

CONSIDERAÇÕES FINAIS

De acordo com o exposto, percebe-se que, de fato os problemas existentes no sistema de água de resfriamento da Usina Serra da Mesa vem provocando diversos inconvenientes, como por exemplo desgastes prematuros em vários componentes, a interrupção dos trabalhos de manutenção do pessoal da divisão de eletromecânica e a indisponibilidade das unidades geradoras. Porém, esses problemas estão sendo minimizados pelo uso de tratamento químico e, recentemente, pela instalação do sistema ATB nas unidades geradoras 02 e 03, a instalação dos filtros de cartucho no sistema de lubrificação dos carvões da caixa de vedação do eixo da turbina e também a limpeza química utilizando-se a unidade remota para limpeza dos trocadores de calor.

Full transcript