Electrical Reliability Services ~ Commissioning Division

  • A division of Emerson Network Power
  • Full Member of the InterNational Electrical Testing Association (NETA)
  • Established 1971 as Electro-Test Inc.
  • In 1998 Mechanical/Electrical Commissioning Services became a service offering of Electrical Reliability Services
  • ERS commissioning and testing services have been offered globally
  • 18 ERS Offices from Seattle, WA to Ft. Meyers, FL
  • 10 HVM Offices services North Eastern United States
  • 300 Field Service Technicians and Commissioning Engineers across the country

ERS Strategy

Success

DST Systems, Inc. / WINCHESTER DATA CENTER

Commissioning of Mechanical System Upgrade & Generator Plant Upgrade

October 7, 2013 1:00PM-2:30PM

Michael Donato, QCxP, LEED AP

Ryan Wagner, QCxP

John Gottwald

Robin Tennison

Project done properly the first time

Meets DST System's needs and expectations

Reliability

Schedule & Budget

Interview Agenda

10 Minutes – Introduction of Emerson Electrical Reliability

Services Commissioning

40 Minutes – Bell/Knott & Associates Corporate

Architects, P.C. Identified topics dated

September 30, 2013

20 Minutes – Project Execution Strategy

15-20 Minutes – Question and Answer

Organization Profile

Mechanical System Upgrades

ERS ~ ITS Relationship

Liebert

ITS - sales rep

DST

Emerson

Network

Power

Electrical Reliability Services

The proposed scope of work supplied to DST is inclusive of all equipment and procedures listed in the RFP. ERS intends to execute this scope of work per the RFP.

<Handout> Please review the sample Cx Script for chiller/cooling tower systems

  • ITS is a Liebert representative, also a member of Emerson Network Power, and the connection from DST to ERS.
  • ERS reports directly to DST, and copies ITS.

Load Testing & Sequencing of Chillers/CRAC & Waterside Economizer in an Active Data Center

Utilize existing building loads for capacity testing and add load using existing equipment in building.

Setpoint manipulation for sequence of operation verification.  Note that supplemental load banks are required for this component and not currently covered under the Cx scope of work.

If combination of the above options do not reach capacity, there may be a need for seasonal testing.

Commissioning Staff

Planned Site Time

- Tim Brown, Field Engineer A

  • Field Commissioner, Electrical
  • Facebook, NCAR, Agilent, Chesapeake Energy

- Brian Langford, Field Engineer A

  • Field Commissioner, Electrical
  • Google, Bank of America, City Bank, Cerner

- Phillip Pruzensky, Senior Technician

  • Field Commissioner, Mechanical
  • NSA Data Center, Truckee Medical Center

- James Shigley, Senior Mechanical Specialist

  • Field Commissioner, Mechanical
  • 14 years data center Cx experience

Additional Clarification on Site Time

Mechanical System Upgrade

Total 31 Days on site for

Commissioning Tasks

Generator Plant Upgrade

Total 30 Days on site for

Commissioning Tasks

Key Strategies

Michael Donato, Cx Project Manager

  • 14 years data center CxA experience
  • QCxP, University of Wisconsin
  • NETA Level III Technician, 21 years

Reza Hosseini, Mechanical Lead

  • 8 years critical space Cx experience
  • ME, CA Licensed PE
  • Cx as part of the Project Team
  • One common goal
  • Communicate Roles & Responsibilities
  • Early coordination
  • Open team communications

Key Strategies

Advocate contractor pre-testing of systems prior to demonstration testing ~ avoid costs of re-tests

Load Testing & Sequencing of Electrical Systems in an Active Data Center

Perform Load Testing of individual components during startup.

Complete new Systems Testing under load prior to connection to Existing Systems.

Assessment of Risk; Comprehensive Written Procedures; Contingency Planning

Form Agreement

Terms and Conditions addressed by John Gottwald with ITS

Qualifying Project 1

Qualifying Project 2

FedEx Corporate Services

Enterprise Data Center West ~ Colorado Springs, CO

Qualifying Project 3

FORTRUST LLC

Denver Co-Location Data Center

IBM Boulder

Building 022, Data Center Addition

Addition of a 22k sq/ft Data Center to an Existing Critical Space Campus and Central Plant

> Pre-Testing of Critical Equipment > Team Review of Testing Plans

> Methods of Procedure (MOPs) > Off-Peak Test Schedule

Expansion & Commissioning of the 20k sq/ft Phase IV computer room in the operating facility

> Existing System Operationally Verified > Contingency Planning

> Methods of Procedure (MOPs) > Comprehensive Testing Plan

and Review

Construction & Commissioning of New Data Center in the same building as the Existing Operational Data Center, supported by the same infrastructure

> Owner Project Requirement > Contingency Planning

> Methods of Procedure (MOPs) > Temporary Back-up Provisions

> Risk Assessment & Identification > Communication