VERTICAL OPENINGS
Vertical openings contained entirely within a shaft enclosure complying with Section 713 shall be permitted.
Shaft enclosures shall have a fire-resistance rating of not less than 2 hours where connecting four stories or more.
Shaft enclosures shall have a fire-resistance rating of not less than 1 hours where connecting less than four stories.
Penetrations, concealed and unconcealed, shall be permitted where protected in accordance with Section 714.
Where a building is equipped throughout with an automatic sprinkler system, vertical openings for escalators shall be permitted where protected in accordance with Section 712.1.3.1 or 712.1.3.2.
712.1.3.1 Opening Size: Protection by Draft curtain
712.1.3.2 Automatic shutters
Vertical openings between a mezzanine complying with Section 505, and the floor below shall be permitted.
Joints made in or between horizontal assemblies shall comply with Section 715. The void created at the intersection of a floor/ceiling assembly and an exterior curtain wall assembly shall be permitted where protected in accordance with Section 715.4.
712.1.5.1 Joints in or between horizontal assemblies.
712.1.5.2 Joints in or between non fire-resistance-rated floor assemblies.
In other than Group H occupancies, atriums complying with Section 404 shall be permitted.
In other than Groups I-2 and I-3, a vertical opening that is not used as one of the applications listed in this section shall be permitted if the opening complies with all of the items below:
Vertical openings in parking garages for automobile ramps, elevators and duct systems shall comply with Section 712.1.10.1, 712.1.10.2 or 712.1.10.3, as applicable.
Elevators: Vertical openings for elevator hoist ways in open or enclosed parking garages
Automobile ramps: Vertical openings for automobile ramps in open and enclosed parking garages
Duct systems: Vertical openings for mechanical exhaust or supply duct systems in open or enclosed parking garages.
Vertical openings containing exit access stairways or ramps in accordance with Section 1019 shall be permitted.
Vertical openings for floor fire doors and access doors shall be permitted where protected by Section 712.1.13.1 or
712.1.13.2.
Access Door
Horizontal fire door assemblies
Skylights and other penetrations through a fire-resistance-rated roof deck or slab are permitted to be unprotected, provided that the structural integrity of the fire-resistance-rated roof assembly is maintained.