VERTICAL OPENINGS

SHAFT ENCLOSURE

Vertical openings contained entirely within a shaft enclosure complying with Section 713 shall be permitted.

Shaft

Shaft Enclosure connecting 4 or more stories

Shaft enclosures shall have a fire-resistance rating of not less than 2 hours where connecting four stories or more.

Shaft Enclosure connecting less than 4 stories

Shaft enclosures shall have a fire-resistance rating of not less than 1 hours where connecting less than four stories.

Penetrations

Penetrations, concealed and unconcealed, shall be permitted where protected in accordance with Section 714.

Penetrations

Escalator Openings

Where a building is equipped throughout with an automatic sprinkler system, vertical openings for escalators shall be permitted where protected in accordance with Section 712.1.3.1 or 712.1.3.2.

712.1.3.1 Opening Size: Protection by Draft curtain

712.1.3.2 Automatic shutters

Escalator

Mezzanine

Vertical openings between a mezzanine complying with Section 505, and the floor below shall be permitted.

Mezzanine

Joints

Joints made in or between horizontal assemblies shall comply with Section 715. The void created at the intersection of a floor/ceiling assembly and an exterior curtain wall assembly shall be permitted where protected in accordance with Section 715.4.

712.1.5.1 Joints in or between horizontal assemblies.

712.1.5.2 Joints in or between non fire-resistance-rated floor assemblies.

Joints

Ducts And Air Transfer Openings

  • Penetrations by ducts and air transfer openings shall be protected in accordance with Section 717.
  • Grease ducts shall be protected in accordance with the Saudi Mechanical Code (SBC 501).

Ducts & Air Transfer Opening

Atrium

In other than Group H occupancies, atriums complying with Section 404 shall be permitted.

Atrium

Two-story Opening

In other than Groups I-2 and I-3, a vertical opening that is not used as one of the applications listed in this section shall be permitted if the opening complies with all of the items below:

  • Does not connect more than two stories.
  • Does not penetrate a horizontal assembly that separates fire areas or smoke barriers that separate smoke compartments.
  • Is not concealed within the construction of a wall or a floor/ceiling assembly.
  • Is not open to a corridor in Group I and R occupancies.
  • Is not open to a corridor on non sprinklered floors.
  • Is separated from floor openings and air transfer openings serving other floors by construction conforming to required shaft enclosures.

Two-Story Openings

Parking Garage

Vertical openings in parking garages for automobile ramps, elevators and duct systems shall comply with Section 712.1.10.1, 712.1.10.2 or 712.1.10.3, as applicable.

Elevators: Vertical openings for elevator hoist ways in open or enclosed parking garages

Automobile ramps: Vertical openings for automobile ramps in open and enclosed parking garages

Duct systems: Vertical openings for mechanical exhaust or supply duct systems in open or enclosed parking garages.

Parking Garages

Exit access stairways and ramps

Vertical openings containing exit access stairways or ramps in accordance with Section 1019 shall be permitted.

Exit access stairways & ramps

Opening

Vertical openings for floor fire doors and access doors shall be permitted where protected by Section 712.1.13.1 or

712.1.13.2.

Openings

Access Door

Horizontal fire door assemblies

Skylight

Skylights and other penetrations through a fire-resistance-rated roof deck or slab are permitted to be unprotected, provided that the structural integrity of the fire-resistance-rated roof assembly is maintained.

Skylights