MRI sequenties

No description
by

Annelies van der Plas

on 8 December 2013

Comments (0)

Please log in to add your comment.

Report abuse

Transcript of MRI sequenties

MRI sequenties
A. van der Plas
Medisch Centrum Alkmaar

Type sequentie
Siemens
Philips
Spin echo (SE)
Multi spin echo
Fast SE
UltraFast SE
IR
STIR
FLAIR
Gradient echo (GE)
Spoiled GE
Ultra fast GE
Steady state GE
contra. enha. steady state GE
Balanced GE
SE-echo planar
GE-echo planar
Hybride echo
SE
Multi SE
Turbo SE
SSH-TSE, UFSE
IR
STIR
FLAIR
SE
Multi SE, MS
Turbo SE
SSTSE, HASTE
IR/IRM
STIR
FLAIR
FFE
T1-FFE
T1(2)-TFE, THRIVE
FFE
T2-FFE T2
Balanced FFE
SE-EPI
FFE-EPI, TFE-EPI
GRASE
GRE
FLASH
Turbo FLASH, VIBE
FISP
PSIF
True FISP
EPI SE
EPI Perf, EPIFI
TGSE
Spin echo
90 graden puls & 180 graden puls
Sequenties


Doel:
- optimaliseren weefsel (contrast)
- scantijd verminderen
- beperken van artefacten
NB: > 100 verschillende sequenties
Karakteristieken MRI sequentie
Essentieel:
Opties:
- een RF excitatiepuls --> magnetische resonantie
- gradienten voor spatial encoding --> vulling K-ruimte
- signaal aflezen: echo type (spin, gradient) bepaalt het contrast (invloeden van T1, T2 en T2* relaxatie)
- specifieke RF pulsen voor aanpassing contrast: IR, vet satturatie
- reconstructie methode: partial Fourier plane filling, parallele acquisition
- beperken artefacten: saturatieband, flow compensatie
Fast spin echo
Ultra Fast Spin echo
Siemens / Philips: Turbo SE
Siemens: Single Shot Turbo SE (SSTSE), HASTE
Philips: UFSE, SSH-TSE

Nadelen:
- blurring door verschillende TE's
- multipele 180gr pulsen --> verhoogde magnetisatie bij spieren --> zwarter dan op conventionele spin echo
- NIET handig bij zoektocht bloedingen (minder suscept. art)
- J-coupeling (verminderde T2 relaxatie bij vet)
Inversion Recovery (IR)
STIR
FLAIR
Longitudenale vlak & transversale vlak
90 graden puls
Exitatie
Transversale magnetisatie: 0 %
Transversale magnetisatie: 100%
Basis
Larmor frequentie
Fase van proton in transversale vlak
Onthou:
- signaal alleen meetbaar in transversale vlak
- signaal indien protonen 'in fase' draaien
Relaxatie
T1 relaxatie
T2 relaxatie
Spin echo
Gradient echo
Take home message
Algemeen / basics
TR = repetitietijd (tijd tussen RF pulsen)
TE = echo tijd (tijd tussen RF puls en echo)
DRIVE
variant FSE
Na elke echotrein een 90 graden puls --> longitudinale magnetisatie hoog --> grote bijdrage volgende excitatie
Doel: hoge intensiteit vloeistof
Bijv. bij brughoekprotocol
* vaak gecombineerd met FSE
* bepaald weefsel onderdrukken
Doel: verminderde transversale magnetisatie
Axial T2W drive image reveals that the cochlear nerve is absent (black arrow) from the anteroinferior quadrant of the internal auditory canal. The cochlear neural foramen is developmentally occluded (white arrow).
MSK (vettig beenmerg!)
Mammo
Abdomen
Neuro
Hersenen/spinale kanaal
Speerpunten:
- MS
- sub-arachnoidaal bloed
- meningitis
IR voor witte stof (TI 300 ms):
- perventriculaire leukomalacie
- congenitale grijs/witte stof afwijkingen
TI: 1700-2200 ms
TI: 100-175 ms
GEEN 180 graden puls
Voordelen:
- geen 180 graden puls nodig --> verlaagd TE tijd
- kleinere flipangle --> verlaagd TR tijd
Nadelen:
- susceptibileitsartefacten
T1 en T2 regels hetzelfde
Steady State GE
Coherent GE
Theorie: behouden van transversale magnetisatie
-
+
Twee gradient velden:
1. defaserende gradient (spoilers) --> versnelt defasering
2. refaserings gradient (rewinders)--> 'draait het om' --> protonen in fase
Energie 'in' = energie 'uit'
TR is korter dan de T1 en T2 relaxatietijden van het weefsel
Residu transversale magnetisatie
Meestal - TR 20-50 ms
- FA 30-45 gr
- coherent gradient
- incoherent gradient
Rewinding = refasering van de opgebouwde transversale magnetisatie.
Gevolg: protonen in fase bij volgende excitatie
Traditioneel een lange TE, dus T2*
Voordelen:
- snel ++ (korte TR)
- gevoelig voor flow
- 3D volume acquisitie
Nadelen:
- verminderde SNR
- toename suscep.
- geluid!
Incoherent (spoiled) GE
angiografie
myelografie
artrografie effect
Opgebouwde (residu) transversale magnetisatie gaat verloren
Alleen transv. magnetisatie van voorgaande excitatie bewaard
Tegenovergstelde van rewinding
Met name T1 (PD) gewogen opgename
Voordelen:
- snel ++
- 3D volume acquisitie
- goede SNR & anatomische detail in 3D
- gebruikt worden met gadolinum
Nadelen:
- slechte SNR in 2D
- geluid!
- in/ uit fase scans
- angiografie met gadolinum
Balanced GE
Gemodificeerde coherent GE
Gebalanceerd gradient systeem; correctie fase errors van flow bloed/liquor.

Protonen bloed/liquor in fase --> hoog signaal
Grotere FA en kortere TR's vergeleken met coherent GE
Voordelen:
- sneller t.o.v. coherent GE
- betere SNR
Oorspronkelijk:
- hart
- grote vaten
Nu ook:
- wervelkolom (m.n. cervicaal)
- interne gehoorgang
- gewrichten
- abdomen
GE-EPI
EPI = echo planar imaging
Echo trein van gradienten
K-ruimte wordt in 1 TR verkregen
Gebruikt bij:
- hart/coronairen
- functionele MRI
- interventie
Nadeel:
- veiligheid van patient!
- artefacten (chemical shift, blurring/ghosting, )
Voordeel:
- snel ++
Gradient echo:
- Coherente GE = T2
- Incoherente (spoiled) = T1

Praktisch:
- zuivere T2 (spin echo) vs. T2* (gradient)
Balanced FFE (Siemens) TrueFISP (trufi) (Philips)
Spin echo:
- Fast Spin Echo
- IR (STIR/FLAIR)

Siemens: T1-FFE (fast field echo)
Philips: FLASH (fast-low-angle shot)
Siemens: FFE (Fast Field Echo)
Philips: FISP (Fast Imaging with Steady StatePrecession)
Siemens: T1-FFE (fast field echo)
Philips: FLASH (fast-low-angle shot)
Praktijk: deoxyhemoglobuline, methemoglobuline, hemosiderine
Multipele cavernomen
Fast Spin Echo vs FFE
FLAIR vs FFE
Bloeding bij thalamus glioom
PVNS
SWI (Susceptibility weighted imaging)
Uitbuiten van artefacten van bloed/ijzer/kalk
Variant van gradient echo
Praktijk:
- kleine hemorrargische laesies (DAI!!)
- kleine vaten / venografie
- ijzerdeposities neurodegeneratieve ziekte (Parkinson, Huntington & Alzheimer)
- evaluatie tumoren, vasculitis en epilepsie
Conventionele GE
SWI
GE-EPI
Functionele MRI
Perfusie MRI
GR- EPI
T2 TSE STIR
FLASH + wash in
wash-out
Combinatie van radiofrequente pulsen en gradienten (zijn de 'bouwblokken')
Voordelen:
SW
- prothese --> kies (fast) spin echo
- bloed --> kies gradient
- gadolinium NIET i.c.m. STIR
Bronnen
- Westbrook. MRI in Practice. 2011
- Chavhan et al. Steady-State MR Imaging Sequences: Physics, Classification, and Clinical Applications. Radiographics 2008
- Chavhan et al. Principles, Techniques, and Applications of T2*- based MR Imaging and Its Special Applications. Radiographics 2009.
- Morelli et al; An Image-based Approach to Understanding the Physics of MR Artifacts. Radiographics 2011.
- Blink. MRI Principes
- IMAIOS
& veelvoorkomende pathologie
- minder susceptibilteitsartefachten
bij prothesen
- goed voor MSK, abdomen en niet-
circulerende vloeistof: MRCP, Uro-MRI.
- minder gevoelig voor beweging
NIET icm Gadolinum!!
Full transcript