Loading presentation...

Present Remotely

Send the link below via email or IM

Copy

Present to your audience

Start remote presentation

  • Invited audience members will follow you as you navigate and present
  • People invited to a presentation do not need a Prezi account
  • This link expires 10 minutes after you close the presentation
  • A maximum of 30 users can follow your presentation
  • Learn more about this feature in our knowledge base article

Do you really want to delete this prezi?

Neither you, nor the coeditors you shared it with will be able to recover it again.

DeleteCancel

Make your likes visible on Facebook?

Connect your Facebook account to Prezi and let your likes appear on your timeline.
You can change this under Settings & Account at any time.

No, thanks

VENTILATION DU RÉSEAU D'ÉVACUATION

No description
by

ELAINE COUTURE

on 26 March 2013

Comments (0)

Please log in to add your comment.

Report abuse

Transcript of VENTILATION DU RÉSEAU D'ÉVACUATION

Définition et
Fonctionnement
des Tuyaux
de Ventilation VENTILATION DU RÉSEAU
D'ÉVACUATION VENTILATION INTERNE D'ÉTAGE. C'EST UN TUYAU QUI SERT À LA FOIS DE RENVOI ET D'ÉVENT PAR L'INTÉRIEUR. TUYAU DE VENTILATION D'ÉQUILIBRAGE: TUYAU QUI SERT À ASSURER UNE CIRCULATION D'AIR SUPPLÉMENTAIRE ENTRE LE RÉSEAU D'ÉVACUATION ET DE VENTILATION DIAMÈTRE ET LONGUEUR DÉVELOPPÉE D'UNE COLONNE DE VENTILATION PRIMAIRE ET SECONDAIRE. POUR DÉTERMINER LA GROSSEUR D'UNE COLONNE DE VENTILATION PRIMAIRE OU SECONDAIRE, IL EST NÉCÉSSAIRE DE CONNAÎTRE LES DONNÉÉES SUIVANTES: BUT DE LA VENTILATION De facilité l'écoulement des eaux usées à l'intérieur
du réseau d'évacuation vers le réseau d'égout public. TUYAU DE VENTILATION D'UTILITÉ. TUYAU DONT LES EXTRÉMITÉS SONT RACCORDÉES EN BOUCLE AU RÉSEAU D'ÉVACUATION. CONCLUSION: IL EST MAINTENANT À VOUS DE DÉMÊLER LES NOMS ET LES TYPES DE TUYAUX AFIN D'UTILISER LES BONS TABLEAUX POUR VOS CALCULS DE DIAMÈTRE DE TUYAUX DE VENTILATION. COLONNE DE VENTILATION PRIMAIRE CELLE-CI CORRESPOND AU PROLONGEMENT
D'UNE COLONNE DE CHUTE AU DESSUS DU RACCORDEMENT D'UN APPAREIL. PHÉNOMÈNE DE SIPHONNAGE:

Vous avez sûrement déjà essayé de boire avec
une paille et tenter de boucher l'extrémité de
celle-ci afin d'empêcher le liquide de sortir vers
le bas !? N'est-ce pas ?

Ce phénomène est le même à l'intérieur du
réseau d'évacuation de votre maison. ON PRÉVIENT LES RETOURS D'AIR VICIÉ DANS
LES BÂTIMENTS EN PROVENANCE DU RÉSEAU D'ÉVACUATION, PAR LA MISE EN PLACE D'UN SIPHON SUR CHAQUE APPAREIL. L'EAU LOGÉE DANS CE QU'ON APPELLE LA GARDE D'EAU, SERT DE JOINT ÉTANCHE QUI EMPÊCHE LE PASSAGE DES GAZ DES ÉGOUTS DANS LE BÂTIMENT. PLOMBERIE L'Entrée d'air dans le
réseau empêchera le
siphonnement de la
garde d'eau dans les
tuyaux. air garde d'eau LES PRINCIPAUX TYPES D'ÉVENTS QUE L'ON RENCONTRE DANS UN RÉSEAU DE VENTILATION
D'UN RÉSEAU D'ÉVACUATION SONT LES SUIVANTS:
1- COLONNE DE VENTILATION PRIMAIRE
2-TUYAU DE VENTILATION INDIVIDUEL OU COMMUN
3-VENTILATION INTERNE D'ÉTAGE OU PLUSIEURS ÉTAGES
4-TUYAU DE VENTILATION SECONDAIRE
5-TUYAU DE VENTILATION D'ÉQUILIBRAGE
6-TUYAU DE VENTILATION D'UTILITÉ
7-COLONNE DE VENTILATION SECONDAIRE
8-COLLECTEUR DE VENTILATION
9-BRANCHEMENT DE VENTILATION
10-VENTILATION D'UN RÉSERVOIR DE CAPTATION
11-VENTILATION D'UN SÉPARATEUR D'HUILE
12-VENTILATION D'UN RÉSERVOIR D'ALIMENTATION. CLASSEMENT DES TUYAUX DE VENTILATION DANS CETTE PORTION DE TUYAU
IL N'Y A PAS D'EAU QUI Y
CIRCULE. TUYAU DE VENTILATION COMMUNE: Tuyau vertical qui assure la ventilation de deux appareils
reliés au moyen d'un raccord double ou de deux raccords simples.
CE DISPOSITIF PERMET LA VENTILATION DE DEUX APPAREILS DOS À DOS OU CÔTE À CÔTE. POSITION DE L'ÉVENT: LA POSITION DE L'ÉVENT PEUT AFFECTER SON RENDEMENT.
LE TABLEAU DE LA FIGURE 7.1 VOUS DONNERA LES DONNÉES PERMISES. VOIR TABLEAU 5.7.1 TUYAU DE VENTILATION SECONDAIRE: CELUI-CI EST LE PROLONGEMENT DE LA VENTILATION INTERNE. INSTALLÉ AUX ENDROIT IMPRATICABLES: COMME SOUS UN ÎLOT DE CUISINE. COLONNE DE VENTILATION SCONDAIRE TOUTE COLONNE DE CHUTE DÉSSERVANT DES APPAREILS SANITAIRES RÉPARTIS SUR PLUS DE 4 ÉTAGES DOIT ÊTRE ASSOCIÉE À UNE COLONNE DE VENTILATION SECONDAIRE.
(MINIMUM REQUIS PAR LE CODE DE PLOMBERIE) COLLECTEUR DE VENTILATION: TUYAU QUI AMÈNE À L'AIR LIBRE
PLUSIEURS COLONNES DE
VENTILATION
PRIMAIRE OU SECONDAIRE. BRANCHEMENT DE VENTILATION TUYAU DE VENTILATION DONT L'EXTRÉMITÉ INFÉRIEURE EST RACCORDÉE À LA JONCTION DE PLUSIEURS TUYAUX DE CE TYPE ET L'EXTRÉMITÉ SUPÉRIEURE, À UNE COLONNE DE VENTILATION PRIMAIRE, UNE COLONNE DE VENTILATION SECONDAIRE OU UN COLLECTEUR DE VENTILATION, OU ENCORE, DÉBOUCHE À L'AIR LIBRE.
LORSQUE 2 OU PLUSIEURS TUYAUX DE VENTILATION SECONDAIRES, INDIVIDUELLE, COMMUNE, DE PUISARD, OU ENCORE D'ÉQUILIBRAGE SE CROISENT, LA COMBINAISON DES 2 ÉVENTS SE NOMME "BRANCHEMENT DE VENTILATION". CES TROIS DERNIERS TUYAUX DE VENTILATION SONT RACCORDÉS À LEUR APPAREIL
RESPECTIF. 1- LE DIAMÈTRE DE LA COLONNE DE CHUTE;
2- LE NOMBRE DE FACTEURS D'ÉVACUATION;
3- LA LONGUEUR DÉVELOPPÉE DE CETTE COLONNE DE VENTILATION EN VOUS FIANT AU TABLEAU DE LA PAGE 196 b). SELON LE TYPE DE TUYAU DE VENTILATION.
Full transcript