Loading presentation...

Present Remotely

Send the link below via email or IM

Copy

Present to your audience

Start remote presentation

  • Invited audience members will follow you as you navigate and present
  • People invited to a presentation do not need a Prezi account
  • This link expires 10 minutes after you close the presentation
  • A maximum of 30 users can follow your presentation
  • Learn more about this feature in our knowledge base article

Do you really want to delete this prezi?

Neither you, nor the coeditors you shared it with will be able to recover it again.

DeleteCancel

Make your likes visible on Facebook?

Connect your Facebook account to Prezi and let your likes appear on your timeline.
You can change this under Settings & Account at any time.

No, thanks

iManager M2000 and RF

No description
by

Muhammad Naeem

on 24 October 2013

Comments (0)

Please log in to add your comment.

Report abuse

Transcript of iManager M2000 and RF

Presented by Muhammad Naeem iManager M2000 and RF Agenda Service Effecting Alarms Core: How iManager M2000 can be helpful to RFP? 1. GSM Cell Out of Service
2. E1/T1 Loss of Signal
3. OML Fault
4. Level 1 VSWR Alarm
5. Level 2 VSWR Alarm
6. RF Unit Maintenance Link Failure
7. RF Unit VSWR Threshold Crossed
8. RF Unit RX Channel Fault
9. Clock Reference Abnormal Alarm
10. E1 Local Alarm
11. E1 Remote Alarm
12. TRX Hardware Alarm
13. TRX LAPD Link Interrupt
14. TRX Communication Alarm
16. Cell Logical Channel Failure Thank You! Topics Covered: RF Planning - Ufone PTML a. Dumps Extraction
- Using Configuration Management Express (CME)

b. Stats/KPIs extraction
- Using PRS
- Using iManager M2000 Client

c. Alarms Extraction
- Alarms List
- Alarms Log
- How to extract alarms other then displayed in alarms list or alarm logs?
- Alarms on the Maintenance Client d. Service affecting alarms

e. Other useful features of Maintenance Client
- TRX Specifications and Status
- Number of E1 Ports and Status
- Monitor Channel Status
- EDGE Support Check
- Trace

f. Other useful features of CM Express
- BTS Topology
- Cell Parameters
- TRX Configuration Express

g. Other useful features of iManager
- Network Performance Reports GSM Cell Out of Service • The BSC periodically checks the BCCH TRX and the RSL of the BCCH TRX. This alarm is generated when the RSL of the BCCH TRX is faulty or the BCCH TRX is unavailable for use. Attributes Alarm ID Alarm Severity Alarm Type
21801 Major Fault All the speech services and data services are disrupted in the cell. Impact on System • Manual blocking (Alarm: GSM Cell Manually Blocked)
• Other OM operations (for example, modify Main BCCH).
• BTS power failure
• Other causes: The BTS is unavailable for use for a short period because the LAPD links or TRX attributes are adjusted; the BTS is reset because of the BSC reset; the BTS is automatically reset; the board is faulty; transmission failure occurs; the data configuration is improper; the BTS boards are manually reset. Level 1 VSWR Alarm The DUP Unit reports a voltage standing wave ratio (VSWR) alarm when detecting that the VSWR on antenna port A or antenna port B is greater than Standing Wave Radio Alarm Threshold (default value: 2.0) but smaller than Serious Standing Wave Radio Alarm Threshold (default Value: 3.0). Agenda


Dumps Extraction


KPIs /Stats Extraction


Alarms Extraction


Service Effecting Alarms Agenda


Dumps Extraction


KPIs /Stats Extraction


Alarms Extraction


Service Effecting Alarms Agenda


Dumps Extraction


KPIs /Stats Extraction


Alarms Extraction


Service Effecting Alarms Agenda


Dumps Extraction


KPIs /Stats Extraction


Alarms Extraction


Service Effecting Alarms Dumps Extraction Using CME KPIs/Stats Extraction 1. Using PRS Agenda


Dumps Extraction


KPIs /Stats Extraction


Alarms Extraction


Service Effecting Alarms Procedure: 1. Open Planned Area --> RFP North

Maintenance --> CME: Area Management --> Planned Area --> Open Planned... --> RFP North

2. Synchronize NEs

CME: Area Management --> Planned Area --> Synchronize Planned Data

3. Extract Dumps

GSM Application --> Export Data Agenda


Dumps Extraction


KPIs /Stats Extraction


Alarms Extraction


Service Effecting Alarms 2. Using iManager M2000 Radiated power of the antenna lowers and coverage reduces. Impact on System Attributes Alarm ID Alarm Severity Alarm Type
5326 Major Fault Level 2 VSWR Alarm The DUP Unit reports a VSWR Alarm when detecting that the VSWR on antenna port A or B is greater than Serious Standing Wave Ratio Alarm Threshold (default value: 3.0). The DTRU connected to the DUP Unit stops outputting power when the alarm is triggered. The services wil recover only after the alarm is cleared and the DTRU is manually reset. Impact on System Attributes You will have to
click on a BSC or BTS
in order to make below
shown menu appear. Alarms Extraction 1. Browse Alarm List Agenda


Dumps Extraction


KPIs /Stats Extraction


Alarms Extraction


Service Effecting Alarms 2. Browse Alarm Logs 3. Extracting alarms for specific time 4. Alarms extraction from Maintenance Client OML Fault Attributes This alarm is generated when the BSC detects the LAPD_OML disconnection between the BSC and the BTS or the BSC detects that the handshake with the BTS times out. Impact on System: • All the BTS services are disrupted when the LAPD_OML is disconnected.
• Fifteen minutes after the LAPD_OML is disconnected, the corresponding BTS will be reset automatically. Possible Causes • The connections of the antenna feeder transmit channel are faulty.
• The DUP Unit hardware is faulty. Possible Causes Alarm ID Alarm Severity Alarm Type
5328 Critical Fault • The connections of the antenna feeder transmit channel are faulty.
• The DUP Unit hardware is faulty. Alarm ID Alarm Severity Alarm Type
21807 Major Fault • The transmission equipment or transmission link between the BSC and the BTS is faulty.
• The Abis interface board on the BSC is faulty.
• There is no power supply to the BTS.
• The TMU board or E1 surge protection board of the BTS is faulty. Possible Causes E1/T1 Loss of Signal This alarm is reported when Loss of Signal (LOS) is detected on the E1/T1 RX port Imapct on the System The ongoing services carried on the E1/T1 link are disrupted. • The E1/T1 link is incorrectly configured.
• The E1/T1 transmission link is faulty.
• The local device is faulty.
• The E1/T1 transmission trunk is faulty.
• The peer device is faulty. Possible Causes Alarm ID Alarm Severity Alarm Type
25800 Major Fault Attributes Possible Causes RF Unit Maintenance
Link Failure This alarm is reported when the maintenance link between the BBU and the RF unit malfunctions. Impact on System The ongoing services carried on the RF unit are disrupted. Attributes Alarm ID Alarm Severity Alarm Type
26235 Critical Fault • The CPRI link between the current-level RF unit and the BBU or upper-level RF unit is broken.
• The RF unit is not powered on or running improperly.
• The RF unit hardware is faulty. Possible Causes RF Unit VSWR Threshold
Crossed This alarm is reported when the VSWR at the antenna port of the TX channel of an RF unit is higher than the preset threshold. Impact on System • The preset VSWR threshold is very low.
• The feeder connector on the antenna port is loose.
• The feeder is bent, deformed, or damaged.
• The VSWR detection circuit of the RF unit is faulty. Alarm ID Alarm Severity Alarm Type
26529 Critical Fault Possible Causes Attributes If return loss at the antenna port is excessive, the RF unit automatically switches off the TX channel (TX Services disrupted). If it is relatively large, the output power of the RF unit decreases and the cell coverage shrinks. RF Unit RX Channel
Fault This alarm is reported when the average RX level difference between main and diversity RX channels of the RF unit exceeds the statistical RX level difference in each measurement period (32 dB by default, user-definable). Impact on System The UL receive sensitivity drops, and the coverage area is reduced. If the faulty TRX is a BCCH TRX, the coverage area of the cell is reduced, which may lead to the drop of the handover success rate. Alarm ID Alarm Severity Alarm Type
28011 Critical Fault • The RF connections at the diversity RX port of the RF unit are loose or broken.
• The RF unit is damaged. Attributes Possible Causes Clock Reference
Abnormal Alarm TRX Hardware Critical
Alarm The alarm is reported when any of the following conditions occurs: (1) The TRX phase-locked loop is faulty, which causes the TRX unavailable. (2) The DSP download fails. (3) The power unit, power amplification unit, flash memory or RF module is faulty, which causes the TRX unavailable. All the services of the DTRU will be interrupted upon occurrence of this alarm. Impact on System Attributes Alarm ID Alarm Severity Alarm Type
4136 Critical Fault • The DTRU hardware is running abnormally.
• The DTRU hardware is faulty. Possible Causes TRX Communication Alarm The alarm is reported when the handshake between Carrier Module and TMU at the CBUS2 link layer fails. All the services of the DTRU will be interrupted upon occurrence of this alarm. Impact on System Attributes Alarm ID Alarm Severity Alarm Type
4192 Critical Fault Possible Causes • The DTRU hardware is running abnormally.
• The DTRU hardware is faulty. The alarms listed above are a few among all the service effecting alarms but can be very critical. These should be monitored very carefully. Other than these there are other BTS, Cell, TRX and Channel alarms that occur occasionally. Secondly PS alarms are not stated here. Alarms Help For help on a specific alarm double click it and click on the blue link which states for the details on it. Note: A detailed of the service effecting alarms will be affixed next to iManager Client for quick reference. Functions of iManager M2000:
• Fault Management
• Configuration Management
• Asset Management
• Performance Management
• Security Managment FCAPS Queries Please...? • Accessibility Report
• Call Drop Cell Report
• Congestion Cell Report
• Extra Busy Cell Report
• Extra Idle Cell Report
• GSM BSC KPI Report
• Mobility Report
• Resource Utilization Report
• Retainability Report
• Worst Cell Report GSM Network Performance Monitoring Report - Using iManager Other Features LMT Features This alarm is reported when BTS looses synchronization with upper level clock Impact on System Attributes Possible Causes Alarm ID Alarm Severity Alarm Type
4708 Critical Fault • Faulty clock module
• Abnormal Clock of the transmission unit
• Abnormal upper level clock There might be an offset between the clock of BTS and that of other BTSs upon occurrence of this alarm. This might cause MS handover failure and call drops. TRX and EDGE Status Trace CM Express View Time Slots on E1s TRX Configuration Cell Parameters