L2 FE by R. Fields

Workshop activities for level 2 FE learners at Chesterfield College
by

RUSSELL FIELDS

on 26 November 2014

Comments (0)

Please log in to add your comment.

Report abuse

Transcript of L2 FE by R. Fields

Steel trunking
Steel conduit
Trunking bend
Trunking tee
Installations
Trunking accessories
FP200 PVC conduit
Workshop rules
When everything is tidy, everyone can go.
First fix conduit
2 way and intermediate lighting
A1 ring final circuit
Circuit information
Circuit information
Economy 7 heating
Circuit information
EAL Assessments
1
2
3
4
5
6
7
8
9
10
A
B
C
D
Bubble
Conduit Information
Testing
Steel tray
90 degree Tray bend
Cut 3 pieces of tray at:-
300mm
300mm
80mm
then file all edges smooth.
Cut the 80mm piece in half long ways
Remove all green edges
by filing the outside corner.
then file all edges smooth.
Lay the pieces in order
Bottom
Middle
Top
Drill and fix together
with 6mm roofing bolts
Introduction
remember Use
goggles
1
Stretch and challenge
Wo/man v Board
Circuit details
Images
Nearly as good as Russ
What the?
Very poor!
Not bad
FCU
FCU
FCU
Panel wiring
Conduit challenge
thread conduit for 1 minute
Name

Distance
B Slack 20mm
N Hall 17mm
C Marriot 11mm



.

Data cable
Layout diagram
FE Ben Slack 10/4/14
Make a cable jack from steel conduit
S-PLAN CENTRAL HEATING SYSTEM
SCHEMATIC DIAGRAM
HALL OF FAME
HALL OF FAME
HALL OF FAME
TERMINATING AN RJ45 JACK
Radiators
1. flow with stat
2. warm air convection
3. bleed nipple
4. cold air convection
5. warm heat radiation
6. return
information
red dotted lines are 8 links to be installed in the wiring centre.
HALL OF FAME
bridge in 100mm steel trunking
HALL OF FAME
terminating RJ45 plate
keep some twist
terminating rj47 jack
cut at 10mm
materials and specialist tools
cat 5e data cable
rj45 plug
rj45 face plate
rj45 crimping tool
rj45 tester
punch down tool
images
Cat5e data cable
terminate two rj45 face plates as quick as possible.
(30 second penalty if they do not function)
name: time:
nathan Hall 4:51
ben slack 5:40
curtis marriot 5:40
George lomas 5:58
Alistair johnson 8:23
Functional skills

all
most
some
special
recognition
2013-14
Sumatra Mission
Preparation
briefing
letter from
mahyadi
diagrams
testing
variation order sum/1028
SCHEMATIC DIAGRAM
Radiators
1. flow with stat
2. warm air convection
3. bleed nipple
4. cold air convection
5. warm heat radiation
6. return
red dotted lines are 8 links to be installed in the wiring centre.
who is Mahyadi Panngabean?
who is Mahyadi Panngabean?
2013-14
fe GROUP B PLASTERING
app thomas truman 16.6.14
martyn shore 16.6.14
links to industry
In the working environment terminating a distribution board is what all electricians take the most pride in.
Having evidence of a neat distribution board may make you stand out above the rest when looking for work.
links to industry
Data Engineer is a full time job.
As a Data engineer you will install containment then wire and connect data cables.
The containment will be the same as you have learnt on this course.
fe Jake wilmot 18.6.14
2013-14
After numerous attempts by apprentices and full-time learners, these was the only boards that worked first time.
Curtis Marriott and Alistair Johnson 19/6/14
Cat5e data cable
terminate two rj45 face plates as quick as possible.
(30 second penalty if they do not function)
nathan Hall 4:51
this will take some beating
lauren smith and garion richardson 25/6/14
links to industry
Although it is now common practice to install Combi-boilers where all components are contained in one unit.
Many older properties still have S-Plan heating systems which often need servicing and maintaining.
links to industry
Panel wiring companies purely build, wire and connect panels.
this is a full time job for many people.
information
reference methods
lighting
A
B
basic
tray work
install two 2 gang 2-way switches and 2 lamps.
each lamp to be controlled from both switches. to be wired loop-in at light method.
steel conduit puzzle
pvc/pvc lighting
sy cable
cable tray bridge
swa cable
safe isolation
assessment
allow enough length for whatever you are terminating in to
Trim the steel braiding to 44mm
Then split and twist into two tails
Place a brass washer
on to the gland
Wrap each
braid clockwise
Place another brass washer to sandwich the braids
why sy cable?
SY cable has fine stranded conductors which are the most suitable when connecting to vibrating equipment e.g. motors.
Strip the outer
clear PVC sheath
remember your knife training!!!
recycle all cables in the green bin
Feed the two braids down the 2 slots
then tuck in to the opposite slot
The gland is now ready to terminate in to an enclosure
Wrap tape around the cable
Remove the outer
sheath using a knife
Using a knife remove
the sheath covered in tape.
Position the armourings just before the gland threads
Use a locknut to fix
the gland and 'banjo' to the enclosure.
Why steel wire armoured cable?
The steel wire armourings provide excellent mechanical protection. this cable is used in industrial environments and can be buried in a garden.
using a junior hack-saw, cut around the cable half way in to the steel armourings
The armourings should now snap off
very easily!!!!
Place the shroud and gland nut on the cable
Spread out the armourings
Tighten the gland nut on to the gland
Ensure all wires are clamped and not crossed
Use a 6mm nut and bolt to connect the banjo
recycle all cables in the green bin
recycle all cables in the green bin
recycle all cables in the green bin
recycle all cables in the green bin
cutting
and threading
bending
FP200 and PVC conduit
ring final circuit, in singles in and pvc conduit
ring final circuit in
pvc/pvc cable
pvc conduit basics
steel trunking
construction
steel trunking
basics

step 1
step 2
finished product
installation
you will need 6 male brass bushes
and 3 steel couplings.
videos
good communication is vital
how not to make an electric guitar
50 Volts can kill this is 25,000 Volts
don't be a doofus
Trackers
appeals procedure
Full transcript