Loading presentation...

Present Remotely

Send the link below via email or IM

Copy

Present to your audience

Start remote presentation

  • Invited audience members will follow you as you navigate and present
  • People invited to a presentation do not need a Prezi account
  • This link expires 10 minutes after you close the presentation
  • A maximum of 30 users can follow your presentation
  • Learn more about this feature in our knowledge base article

Do you really want to delete this prezi?

Neither you, nor the coeditors you shared it with will be able to recover it again.

DeleteCancel

Make your likes visible on Facebook?

Connect your Facebook account to Prezi and let your likes appear on your timeline.
You can change this under Settings & Account at any time.

No, thanks

CALCULO DE UNA INSTALACIÓN ELÉCTRICA RESIDENCIAL

No description
by

AIDA CRUZ

on 11 April 2014

Comments (0)

Please log in to add your comment.

Report abuse

Transcript of CALCULO DE UNA INSTALACIÓN ELÉCTRICA RESIDENCIAL

CALCULO DE UNA INSTALACIÓN ELÉCTRICA RESIDENCIAL
ACOMETIDA

CONTADOR

TABLERO DE DISTRIBUCIÓN (Breakers)

CIRCUITOS
(Conductores-Salidas -Control)

El cálculo de los circuitos
residenciales debe ajustarse a las normas del reglamento correspondiente (RETIE).

También debemos tener en cuenta aspectos funcionales como por ejemplo una FUTURA AMPLIACIÓN en la construcción, lo cual implicaría un incremento adicional de circuitos, sin que esto redunde en un cambio de la acometida calculada.

Para tensiones (Voltajes) de 110V y 220V.


En barrios subnormales y zonas rurales, aún se puede encontrar el sistema
bifilar monofásico de 110V

La mayoría de los circuitos
residenciales son del tipo
RESISTIVO

por lo tanto el factor de potencia
es igual a la unidad (FP=1).


Por lo tanto podemos emplear
la formula para potencia:
P= V I

La alimentación para residencias
es del sistema Trifilar monofásico
(del transformador)
Tabla 1: Nº de conductores en un ducto o tubo

Tabla 3: Calibre de conductores y su capacidad en Amperios

Tabla 4: Calculo del factor de demanda

PROCEDIMIENTO
C I R C U I T O S
1. ESTUFA (F - N – F) “es el único trifilar” - 220V

2. TINA (F – F) “Sin neutro” - 220V -

3. ELECTRODOMESTICOS (F – N) - 110V -

4. TOMAS - 110V -

5. LAMPARAS - 110V -

EJEMPLO DE APLICACIÓN
Cálculo para una casa de un piso con techo de losa plana (vista en planta plano arquitectónico)

Circuitos involucrados en el diseño:

Estufa (8000W)
Tina (1500W)
Plancha y lavadora (1000+300 = 1300W)
15 tomas (15*100 = 1500W)
22 lámparas (22*100 = 2200W)
Nevera (250W)

Cálculo de la Acometida
Potencia total sin estufa =
6650W
Utilizando la tabla Nº 4

Primeros 2500W (al 100%) ………….2500W
El resto (4150W) al 30%....................1245W
Subtotal:
3745W

+ Estufa: 8000W
TOTAL :
11745W

11745W / 220V =
53.38A

de la tabla Nº 3 :

2

conductores
Nº 6
(para las dos fases)
1
conductor
Nº 8
(para el neutro)

Tubería: Ø 1 ¼ ”
(tabla Nº1)

Cálculo de la Acometida
Tabla 2: Demanda de Potencia (W) para diferentes salidas

1. Ubicar en un plano arquitectónicos
las salidas

(tomas - bombillos - aparatos eléctricos…)
2. Listar todas las salidas para obtener el total de potencia (W) necesario para la residencia.

3. Con la potencia total utilizando la tabla de factor de demanda: Calcular la acometida

4. Ordenar los circuitos (cuadro de circuitos)
calculando el calibre de conductores, los ductos a utilizar y las protecciones respectivas (breakers) para cada circuito.

RESUMEN DE CÁLCULOS
CUADRO DE CIRCUITOS
ELECTROTECNIA
Universidad Nacional de Colombia
Semestre 01/2014
MSc Wilmer Pérez
BIBLIOGRAFÍA

*Instalaciones eléctricas
Samuel Melguizo

*Instalaciones eléctricas residenciales
Rodrigo Robledo Vélez
Full transcript