Diving beetle inspired adhesive

Agnes bajjaly

1

Situ-Skin Diagnosis

Situ-Skin Diagnosis

Requires adaptable skin adherence and rapid capture of biofluids therfore they developed a device that consists of micro-plungers which contains hydrogels within those cavities (that capture biofluids for enhanced adhesivness and change color for visual indication of PH levels) .This device can attach to skin for real tie and stable health monitoring

Inspired by the male diving beetles they invented a device with the following:

  • Repeatable.
  • Enhanced.
  • And Multidirectional adhesion to human skin in wet and dry environments.
2

The Architecture

The Architecture

Main Features :

  • spatula setae with suction cup-like structures
  • wide mushroom shaped rigid cup which provides sealing
  • soft circular chamber( embedded with hydrogel ) that induces the suction effect
3

Experiments

Testing the adhesivness of PDMS-based patches with different architectures:

  • DIA
  • Mushroom shaped (MCP)
  • cylindrical pillar (CP)
  • Flat samples

DIA: 2.81 (dry )and 2.75 ( wet ) N/cm^2

MCP:2.23 (dry) and 2.09 (wet) N/cm^2

To optimize adhesion soft PDMS with young modulus E=6 - 21 KPa was applied to DIA's widened tip

They tested out different sizes of the DIA ,100,250,500 and 3000μm.DIA with 500μm diameter gave the best results under the same preload

4

Finite Element Testing

  • while applying the preload the volume of the chamber is compressed.

we can see that the stress is concentrated on the thin wall of the DIA.

  • after removing the applied preload pressure drop is induced within the chamber(suction cup effect).
  • during detachment process the volume of the chamber increases creating a pressure difference.

we can see the pressure is concentrated more on the inner edge thus the patch easily undergoes volumetric change within the microcavity while the widened tip prevents leakage and maintains the seal

  • however the MCP could not maintain the seal since stress distribution is concentrated on the exterior edge
5

Preload

Varying Preload experiment

The DIA structure was the only structure that displayed an increase in adhesion strength as the preload increased both in dry and wet conditions,they developped an equation

the suction stress induced volumetric changes can adapt in both dry and wet conditions becuause the DIA's are hydrophobic

σσ

P- initial air pressure

K -estimated constant of volumetric change

F -preload force

R -diameter of DIA tip

N -number of DIA’s per unit area

6

hydrogel embedded DIA

hydrogel embedded DIA

it was found that the addition of hydrogel in the microcavity maximizes the attachment under low preload both in wet and dry conditions

the hydrogel assymetrically absorbs liquid, minimizes the volume of the chamber and pushes out the remaining air forming a vacuum like chamber

saturated adhesion 6 N/cm^2 (dry) and 5.6 N/cm^2 (wet)

5

7

Demonstration

Demonstration

8

Fabrication

Fabrication method and materials

  • To create the DIA they created silicon moulds and treated them with a fluorinated self-assembled monolayer(SAM) solution ((tridecafluoro-1,1,2,2-tetrahydrooctyl)-trichlorosilane (FOTCS);in an argon atmosphere
  • To fabricate the perforated pillars, used a partical filling technique. first ,dispensed drops of polyurethane (PUA) into silicon moulds ,then adding polyethylene terephthalate (PET) film as a supporting backplane .To completing the curing ,the PUA exposed to ulravioled light for several hours .

The fabrication of PDMS pillar done by moulding it with PUA ( a master mould ) .