DRYPRO

No description
by

Kari Mlynar

on 5 August 2014

Comments (0)

Please log in to add your comment.

Report abuse

Transcript of DRYPRO

AIRFLOW/HEPA
STEP 1:
Enter the dimensions of the drying area, then press "DONE"
DryPro will calculate the cubic footage of the area
STEP 2:
Move the slider to the left or right to select how many air changes per hour you want to achieve (minimum of 4 is recommended)
Select the negative air machine you are using by pressing the blue rectangle under the slider

NOW:
"Airflow Needed:" Here,
DryPro will tell you the CFM required
for the amount of air changes per hour you selected
"Units Needed:" Here,
DryPro will tell you the number of negative air machines/air scrubbers required
in the area for the amount of air changes per hour you selected
PSYCHROMETRICS
The Science of Drying
DRYING EQUIPMENT
How much equipment do you need?
DRYPRO
SETTINGS
Here you can:
Set a default email contact:
Every time you press "email" when using the app, your readings and results get sent directly to that recipient.
Set a default room height and preferred distance per air mover
Set US or Metric measurements
Set a default dehumidifier:
This can always be changed in the app.
THEN...
Press
"EMAIL"
to email your results to a pre-set email address, or enter a new one

Press
"Multi-Room"
to calculate CFM and ACH for many areas at one time

Press
"CLEAR"
if you want DryPro to reset the page
from Nu-Tech Cleaning Systems, Inc.
TM
This is where you can manage indoor air quality.
Basic settings to enter before you begin.
PSYCHROMETRICS CONT'D
CALCULATIONS
After you enter your temperature and relative humidity readings,
DryPro calculates:
Grains Per Pound [GPP]
Dew Point
Grain Depression

Press
"email"
to send your readings to the default recipient, or change the recipient manually.
STEP 1: THE "IN" COLUMN
Use a thermohygrometer
to measure the temperature of the air going into the dehumidifier
Enter temperature
in the "Temp F" space in the "In" column
Use a thermohygrometer
to measure the relative humidity going into the dehumidifier
Enter relative humidit
y in the "Rel Humidity" space in the "In" column


STEP 2: THE "OUT" COLUMN
Use a thermohygrometer
to measure the temperature of the air going out of the dehumidifier
Enter temperature
in the "Temp F" space in the "Out" column
Use a thermohygrometer
to measure the relative humidity going out of the dehumidifier
Enter relative humidity
in the "Rel Humidity" space in the "Out" column


STEP 1:
Enter dimensions of the area
Enter the class of water loss
Enter the height of standing water
DryPro calculates the amount of standing water
STEP 2:
Select the dehumidifier you are using
DryPro tells you how many units are required to dry the area
for the first 24 hours
DRYING EQUIP.
DAY 2
STEP 1:
Choose your dehumidifier
Enter the grain depression
reading from the dehumidifier
Press "Add"
Repeat these steps for all of the dehumidifiers in the drying area
STEP 2:
The equipment with blue checkmarks should be left on the job site
Which equipment can be removed after the first 24 hours of drying?
Enter dimensions
Enter class of loss
Choose your equipment
Use this many dehumidifiers and air movers for the first 24 hours
HEATING/COOLING BTU
STEP 1:
Enter
room dimensions
Enter
current temperature
of the area
Enter
the desired temperature
of the area
Select the quality of the area's insulation

DryPro calculates the BTU/hr needed to reach the desired temperature


POWER
STEP 1:
Select the
type of dehumidifiers
you are using
Enter the
number of each type
of dehumidifier you are using
Enter your
cost per kWh

DryPro calculates total amperage

STEP 2:
Enter
total run time
of the equipment
DryPro Calculates kW and total cost
Here you can manage your power distribution on the job site.
Required BTU
Select equipment
Enter cost
Enter run time
DryPro calculates total cost and amperage
Choose your dehumidifier
Press "Add"
THANK YOU