LOSAS ALIGERADAS

No description
by

alexis lopez

on 9 October 2014

Comments (0)

Please log in to add your comment.

Report abuse

Transcript of LOSAS ALIGERADAS

¿Qué es una losa aligerada?
LOSAS ALIGERADAS
LOSAS ALIGERADAS
LOSAS ALIGERaDAS
Puede ser de fibra de vidrio o de poliestireno. Este aligerante no permanece en la losa una vez construida y por eso es recuperable y reutilizable.


Se utiliza en casetones, cajones de madera que pueden quedar embebidos en la losa o pueden ser recuperables para reutilizar o no.


puede ser combinado de tipos de ladrillos según sus dimensiones( ladrillos de 10x20x40 pesa 70N y ladrillo tolete de 20x15x40 pesa 100N)
Aligerantes
Elemento que se coloca para disminuir o mermar el peso muerto de la losa.
¿Qué es una losa aligerada?
MADERA
PORÓN
LADRILLO
tipos de losa aligerada
bidireccionales
Losa aligerada
Placa de entrepiso
Losa nervada
Vigas sucesivas apoyadas sobre elementos estructurales
Separación
Sometimiento a cargas (vivas y/o muertas)
Aligerantes
FUNCIONES
separar espacios verticales
aislamiento

ARQUITECTÓNICA
estructural
soportar cargas
propias
externas
diafragma medio

clasificación
Según la dirección de carga

Según el tipo de material estructural
unidireccionales
elemento estructural en 2 lados (opuestos)
la carga se transmite en una sola dirección
rectangulares
(L x L1/2)

elemento estructural en 4 lados
mayor soporte
L/A « 2

tipos de losa aligerada
concreto pretensado - postensado
concreto reforzado
recuperable
perdido
elementos de una losa aligerada
vigas
viguetas
refuerzos positivos y negativos
refuerzo de temperatura
aligerante
loseta
nuevas
tecnologias
placa fácil
losas alveolares
Perfil metálico o concreto
Bloquelones
Malla térmica
Formaleta?
Prefabricado concreto pretensado
alvéolos
Apoyo directo
bubbledeck
proceso constructivo
la losa queda integrada en una sola pieza monolítica
Reciclado del plástico
Reducción de la contaminación (CO2)
Reducción de materiales
Parada 7 - Uruguay
https://upcommons.upc.edu/pfc/bitstream/2099.1/6081/8/07.pdf
http://www.construmatica.com/construpedia/Forjados_Postesados._Tipolog%C3%ADas_-_Rangos_de_Utilizaci%C3%B3n_-_Predimensionamiento
http://www.unalmed.edu.co/hormigon/archivos/hormigon2/losas2d1a.pdf
http://www.ipc.org.es/guia_colocacion/info_tec_colocacion/sopor_sup_colocacion/estabilidad/forjados_reticulares.html
http://ingenieria.udea.edu.co/~ingcivil/obras_civiles/Presentaciones/Clase%2016%20-%20Losas.pdf
http://dc676.4shared.com/doc/dB4nA-5K/preview.html
http://www.lineaprevencion.com/ProjectMiniSites/IS35/html/2-1-1/2_1_1_1.html
http://civil.cicloides.com/losas/3.2.4/
cibergrafia
En la norma NSR-10 en el titulo E.5 se
proporcionan procedimientos simplificados para el
dimensionamiento y cálculo de este tipo de losas.
Si la losa aligerada lleva loseta inferior debe
cumplir con las disposiciones de la NSR-10 y como mínimo
se debe reforzar con alambrón cada 300 mm en ambas
direcciones o con malla de gallinero con ojo de 25 mm y
tener un espesor mínimo de 20 mm y máximo de 30 mm

E.5.1.5.1.1 — La torta inferior — La torta inferior se construye con un mortero de arena y cemento
con una dosificación mínima de un aparte de cemento por tres de arena. Debe tener un espesor
mínimo de 20 mm y máximo de 30 mm. Se debe reforzar con alambrón cada 300 mm en ambas
direcciones o con malla de gallinero con ojo de 25 mm
E.5.1.5.1.3 — La placa superior — Es un concreto fundido monolíticamente con el sistema de piso.
El espesor de la placa debe ser de 50 mm. La placa se debe reforzar con varilla N° 2 cada 300 mm
en ambas direcciones o con malla electro-soldada equivalente a la cuantía anterior.
E.5.1.5.1.4 — Las viguetas — Son los elementos que contienen el refuerzo principal de la losa. El
ancho de las viguetas debe ser mínimo de 80 mm y su espaciamiento máximo entre ejes será de 600
mm.
C.8.13.2
El ancho de las nervaduras no debe ser menor de 100
mm en su parte superior y su ancho promedio no puede
ser menor de 80 mm; y debe tener una altura no mayor
de 5 veces su ancho promedio.
C.8.13.3
Para losas nervadas en una dirección, la separación
máxima entre nervios, medida centro a centro, no
puede ser mayor que 2.5 veces el espesor total de la
losa, sin exceder 1.20 m. Para losas nervadas en dos
direcciones, la separación máxima entre nervios,
medida centro a centro, no puede ser mayor que 3.5
veces el espesor total de la losa, sin exceder 1.50 m.